  • The clean, seamless design of this thinner than average range hood fits snugly under cabinets and provides quiet and effective ventilation performance. Subtle, multi-speed controls connect to centrifugal blowers while halogen lighting brilliantly accents the easy to clean stainless steel bottom containing dishwasher safe filters. The E661 high performance range hood beautifully combines high style and modern convenience to satisfy even the most discerning homeowner.

    • Boost mode operates at up to 600 CFM; Normal setting operates at a quiet 0.4 sones
    • Large recessed filter area increases capture and fully enclosed filter bottom ensures fast and easy clean-up
    • 3-speed control with boost memorizes last setting and 5-minute delay shut off feature make operation simple and convenient
    • Dual 50-watt halogen lights have last setting memory and transitional theater lighting which intensifies gradually (light bulbs included)
    • Heat Sentry™ detects excess heat and adjusts blower to high automatically to prolong product life
    • Dishwasher safe Stainless Steel filters
  • Video Links

    First Time Homeowner 5: Kitchen Renovation, Today’s Homeowner with Danny Lipford

    Article Links

    5 Kitchen Renovations To Avoid, Consumer Reports

    Clearing the Air, K+BB

    The Kitchen as a Pollution Hazard

    Fixing Stove Hoods To Keep Pollution Out Of The Kitchen

  • Whole House Mechanical Ventilation (WHMV) Specifier

    Code compliant solutions for one and two family dwellings and townhouses up to three stories
     

    To better serve you in determining your customers’ whole house mechanical ventilation (otherwise known as continuous ventilation) needs, Broan-NuTone has developed this on-line tool.  With our CodeKey Specifier you can be confident that the products choose will meet the latest codes and regulations.  Use this tool to make your specification job easier.


    Let’s get started by selecting the state where the dwelling unit will be located. CLICK HERE


  • Accessories OptionalYes
    Accommodates Ceiling HeightN/A
    Blower Air Mover TypeHigh Flow Wheel
    Blower IncludedYes
    Boost ModeYes
    CFM (Airflow)600
    Color/FinishStainless Steel
    Control Feature Filter ReminderNo
    Damper IncludedYes
    Delay Shut OffYes
    Digital ClockNo
    Dishwasher Safe FiltersYes
    Duct Connector Size3-1/4" x 14"
    ENERGY STAR® qualifiedNo
    Filter IncludedYes
    Filter TypeMicroMesh Aluminum
    Flue Accommodates ceilings up to xx ftN/A
    Heat Sentry - Temperature SensorYes
    HVI CertifiedYes
    Light Bulb Quantity2
    Light Bulbs IncludedYes
    Lighting FunctionThree-level
    Lighting TypeHalogen
    Max Sones/100 CFM0.9
    Minimum Height Above Cook Top24"
    Mounting SystemWall
    Mounting TypeUnder Cabinet
    NightlightNo
    Non-Stick CoatedNo
    Product Depth (inches)21-1/2"
    Product Height (inches)5-1/8"
    Product Width (inches)42"
    Rated Amps2.4
    Remote ControlNo
    Sones Certified Horizontal Rectangular High2.5
    Sones Certified Horizontal Rectangular Low0.3
    Sones Certified Vertical Rectangular High2.5
    Sones Certified Vertical Rectangular Low0.4
    Sones Certified Vertical Round HighN/A
    Sones Certified Vertical Round LowN/A
    Switch Control Settings4
    Switch StyleElectronic
    TimerNo
    UL ListedYes
    Voltage120
  • (28 Questions : 33 Answers)

    Product Q&A

    Ask your questions. Share your answers.

     
     
    « Back
     
     
    Has staff answer
    E66130SS
     
    1 answer

    Length of ductwork to the outside

    Customer avatar
    by
    diyer
    Is there a maximum length of the ductwork between the hood and the outside vent? Can you describe the impact of increased distance and the number of 90 degree turns on the optimal operation of this hood? My installation would allow for the use of 3 1/4 X 14" duct, but it will have a number of 90 degree turns. It will vent vertically, then make a 90 to horizontal, then another 90 to vertical, 90 to horizontal and finally last 90 to vertical and a long run to the roof. Would the hood still provide good venting with that setup, or should I seek alternative options for venting?
    Age: 35-44
    Gender: Male
    4 days ago
    Customer avatar
    by
    diyer
    0points
    0out of 0found this question helpful.
    Was this helpful?helpful0unhelpful0

    Answers

    Answer: 
    Thank you for your question. In order to assist you better, please contact our Technical Support group at 800-637-1453.
    16 hours ago
    Customer avatar
    by
    Read all my Q&A
     
    Please wait while more information about BroanCustomerService is loaded.
    Additional information about BroanCustomerService could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0
    Age: 45-54
    Gender: Male
    1 week, 5 days ago
    Customer avatar
    by
    JH
    Danbury ct
    0points
    0out of 0found this question helpful.
    Was this helpful?helpful0unhelpful0

    Answers

    Answer: 
    Thank you for your question on the model E66130SS range hood. A maximum of 30’’ above the cook top is highly recommended for best capture of cooking impurities. Although your installation may not give you the absolute best capture of the cooking impurities, it is close enough to still do a good job.
    1 week, 4 days ago
    Customer avatar
    by
    Read all my Q&A
     
    Please wait while more information about BroanCustomerService is loaded.
    Additional information about BroanCustomerService could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0
    Has staff answer
    E66130SS
     
    1 answer

    Halogen vs LED bulbs

    Customer avatar
    by
    Hes
    NJ
    Can I switch out the Halogen bulbs for LEDs and if so, what is the recommended LED bulb?
    Age: 35-44
    Gender: Male
    1 week, 5 days ago
    Customer avatar
    by
    Hes
    NJ
    0points
    0out of 0found this question helpful.
    Was this helpful?helpful0unhelpful0

    Answers

    Answer: 
    Thank you for your question on the model E66130SS range hood. The E66130SS range hood requires two 120 volt, 50 watt maximum, type MR16, shielded halogen lamps with a GU10 base. We cannot recommend or suggest using any bulbs other than the ones listed in the installation instructions.
    1 week, 4 days ago
    Customer avatar
    by
    Read all my Q&A
     
    Please wait while more information about BroanCustomerService is loaded.
    Additional information about BroanCustomerService could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0
    Has staff answer
    E66130SS
     
    1 answer

    Does the E66130 require a make-up air supply in Deschutes County, Oregon?

    Customer avatar
    by
    Paul
    Bend, OR, USA
    The Broan on-line calculator doesn't list the E661 series
    Age: Over 65
    Gender: Male
    2 weeks, 1 day ago
    Customer avatar
    by
    Paul
    Bend, OR, USA
    0points
    0out of 0found this question helpful.
    Was this helpful?helpful0unhelpful0

    Answers

    Answer: 
    Thank you for your question on the model E66130SS range hood. We do not require a make-up air supply for this range hood, but you may want to check with your local codes for the requirements in your area. The MD8TU make-up air damper is compatible with this model.
    4 days ago
    Customer avatar
    by
    Read all my Q&A
     
    Please wait while more information about BroanCustomerService is loaded.
    Additional information about BroanCustomerService could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0
    Has staff answer
    E66130SS
     
    1 answer

    Does this vent require different exhaust ducting than the Broan QS330SS?

    Customer avatar
    by
    Will vent
    Our current vent needs to be replaced, and it appears to be similar to the Broan QS330SS, with the fan on one side and a 7" circular duct opening. I would rather have the E66130.
    1 month, 3 weeks ago
    Customer avatar
    by
    Will vent
    0points
    0out of 0found this question helpful.
    Was this helpful?helpful0unhelpful0

    Answers

    Answer: 
    Thank you for your question on the model E66130SS and QS330SS range hoods. The E66130SS will vent either horizontally or vertically using 3-1/4” x 14” rectangular duct work but with T461 adapter, changes to 3 1/4" x 10". You will have increased noise and reduced performance. The QS330SS will vent either horizontally or vertically using 3-1/4” x 10” rectangular or vertically using 7” round duct work. You can convert the 3-1/4” x 10” to 7”round, using a model 412H transition.
    1 month, 2 weeks ago
    Customer avatar
    by
    Read all my Q&A
     
    Please wait while more information about BroanCustomerService is loaded.
    Additional information about BroanCustomerService could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0