335Exterior Blower for Broan Elite Range Hoods

  • Overview
  • Continuous Ventilation Selector
  • Make-Up Air Specifier
  • Specifications
  • Accessories
  • Reviews
  • Answers
  • Broan Elite blowers provide high ventilation and reduced sound levels. Made of durable construction to meet the needs of professional-quality home cooktops.

    • Available in 1200 CFM so you can be assured of the power you need to fit your installation
    • Exterior-mount provides the quietest operation; all aluminum construction ensures long life and durability
    • Use with 10" round duct (purchased separately)
    • Requires Model 332KR rough-in kit (purchased separately)
  • Whole House Mechanical Ventilation (WHMV) Specifier

    Code compliant solutions for one and two family dwellings and townhouses up to three stories
     

    To better serve you in determining your customers’ whole house mechanical ventilation (otherwise known as continuous ventilation) needs, Broan-NuTone has developed this on-line tool.  With our CodeKey Specifier you can be confident that the products choose will meet the latest codes and regulations.  Use this tool to make your specification job easier.


    Let’s get started by selecting the state where the dwelling unit will be located. CLICK HERE


  • Range Hood Make-Up Air Specifier

    Code compliant make-up air solutions for domestic range hoods in family dwelling units

     

    To help you determine your make-up air needs, Broan-NuTone has developed this on-line tool.  With our Make-Up Air Specifier you can be confident that the products you choose will meet the latest codes and regulations and satisfy the home’s needs.  Use this tool to make your specification job easier.

     

    Let’s get started by selecting the state where the dwelling unit will be located. CLICK HERE


  • CFM (Airflow)1200
    Duct Connector Size10" Rd.
    Rated Amps3.0
    Voltage120
  • Rated 4.5 out of 5 by 2 reviewers.
    Rated 4 out of 5 by May need to be installed upside down I have an island kitchen stove. If this blower is installed at ground level to the outside of a house it has a ground clearance issue and may need to be installed upside down. I had to fabricate a hood on the exhaust outlet to make it weatherproof. The hood is made of stainless steel so now it looks and works great. August 31, 2014
    Rated 5 out of 5 by Massive Still waiting to be installed, but contractor jokingly said that when we turn on the system I will be able to use as a hair dryer; suck the water right off my hair. Will see, but looks imposing and if it works half as good as it looks it will be 5 stars plus. May 7, 2011
    • 2015-09-01T07:13:21.942-05:00
    • bvseo_lps, prod_bvrr, vn_prr_5.6
    • cp-1, bvpage1
    • co_hasreviews, tv_2, tr_2
    • loc_en_US, sid_6c70c35a-fdc6-4ea1-91db-076d440e26e5, prod, sort_default
    1-2 of 2
  • (36 Questions : 36 Answers)

    Product Q&A

    Ask your questions. Share your answers.

     
     
    « Back
     
     
    Has staff answer
    336
     
    1 answer

    will this interlock with make-up air damper MD6T or SMD6

    Customer avatar
    by
    cam
    dc
     on 336
    Age: 45-54
    Gender: Male
    2 days ago
    Customer avatar
    by
    cam
    dc
    0points
    0out of 0found this question helpful.
    Was this helpful?helpful0unhelpful0

    Answers

    Answer: 
    Thank you for your question on the model 336 exterior mounted exhaust fan and models MD6T and SMD6 make-up air dampers. Please contact the Technical Service Department at 800-637-1453 for assistance.
    18 hours ago
    Customer avatar
    by
    Read all my Q&A
     
    Please wait while more information about BroanCustomerService is loaded.
    Additional information about BroanCustomerService could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0
    Has staff answer
    336
     
    1 answer

    What is the required clearance below a wall mounted fan?

    Customer avatar
    by
    SFArch
    San Francisco
     on 336
    If this was installed low on an exterior wall, what are the minimum clearances to the grade below the exhaust point?
    Age: 25-34
    Gender: Male
    1 month, 2 weeks ago
    Customer avatar
    by
    SFArch
    San Francisco
    0points
    0out of 0found this question helpful.
    Was this helpful?helpful0unhelpful0

    Answers

    Answer: 
    Thank you for your question on the model 336 external blower. If wall-mounted, this should be at least 18" to 24" above the ground. If you have further questions, please contact Technical Support directly at 800-637-1453.
    1 month, 1 week ago
    Customer avatar
    by
    Read all my Q&A
     
    Please wait while more information about BroanCustomerService is loaded.
    Additional information about BroanCustomerService could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0
    Has staff answer
    331H
     
    1 answer

    Do you have a smaller unit

    Customer avatar
    by
    Paul
    Gulf Shores, AL, USA
     on 331H
    I am removing a NuTone model WF-N1N fan that has an 8 inch wall opening. Do you have a similar fan that will replace without enlarging hole in wall? Need approx. 500-600 CFM.
    Age: Over 65
    Gender: Male
    5 months, 2 weeks ago
    Customer avatar
    by
    Paul
    Gulf Shores, AL, USA
    0points
    0out of 0found this question helpful.
    Was this helpful?helpful0unhelpful0

    Answers

    Answer: 
    Thank you for your question on the model 331H external mounted exhaust fan. The 331H requires 10" duct and is the only replacement we would have for the WF1N.
    5 months ago
    Customer avatar
    by
    Read all my Q&A
     
    Please wait while more information about BroanCustomerService is loaded.
    Additional information about BroanCustomerService could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0
    Has staff answer
    332H
     
    1 answer

    I'm running ductwork for the 332H in 2X10 joist space which is only 9 1/4".can i run 8" duct?

    Customer avatar
    by
    mike
    Pittsburgh, PA, USA
     on 332H
    Age: 55-64
    Gender: Male
    6 months ago
    Customer avatar
    by
    mike
    Pittsburgh, PA, USA
    0points
    0out of 0found this question helpful.
    Was this helpful?helpful0unhelpful0

    Answers

    Answer: 
    Thank you for your question on the model 332H exterior mounted blower. The 332H should be used with 10" round duct size only. We do not recommend reducing the duct size for this blower.
    5 months, 3 weeks ago
    Customer avatar
    by
    Read all my Q&A
     
    Please wait while more information about BroanCustomerService is loaded.
    Additional information about BroanCustomerService could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0
    Age: 45-54
    Gender: Female
    6 months ago
    Customer avatar
    by
    ula
    massachussetts
    0points
    0out of 0found this question helpful.
    Was this helpful?helpful0unhelpful0

    Answers

    Answer: 
    Thank you for your question on the model 331H exterior mounted exhaust fan. The 332H is designed for use with the kitchen exhaust systems and we would not have an option for installing this in your application. There should be no problem using the 331H with a custom cover for inside. We would recommend that you contact our Technical Support department directly for further discussion about your application at 800-637-1453.
    6 months ago
    Customer avatar
    by
    Read all my Q&A
     
    Please wait while more information about BroanCustomerService is loaded.
    Additional information about BroanCustomerService could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0
    • 2015-09-01T07:15:06.809-05:00
    • bvseo_lps, prod_bvqa, vn_prr_5.6
    • cp-1, bvpage1
    • co_hasquestionsanswers
    • loc_en_US, sid_6c70c35a-fdc6-4ea1-91db-076d440e26e5, prod, sort_default
    2 3 next>>
    • 2015-09-01T07:15:06.813-05:00
    • bvseo_lps, prod_bvqa, vn_prr_5.6
    • cp-1, bvpage1
    • co_hasquestionsanswers
    • loc_en_US, sid_6c70c35a-fdc6-4ea1-91db-076d440e26e5, prod, sort_default
    2 3 next>>