  • Significantly increase the quality of the air inside your home with a BROAN ERV. Allergens and pollutants within your home can have negative effects on your health. By adding a BROAN ERV to your home's ventilation system, you can ensure that the air within your home is being circulated and the pressure remains balanced.

    The BROAN ERV100HC is perfect for 3,000-4,500 sq. ft. single-family homes and is preferred for use in warmer, humid climates where the cooling season is longer. For air-conditioned homes in humid climates, the ERV100HC will limit the amount of moisture allowed in, while in a dry climate with a humidified home, it will control the amount of moisture expelled to maintain optimal comfort levels. The units are durable, reliable and offer high performance that will be sure to add value and quality to any home. An easy-access side panel makes maintenance quick and convenient with the ability to remove all parts in five minutes or less.

    • Ideal for homes in moderately humid climates from 3,001 to 4,500 square feet
    • Delivers 60 to 142 CFM of whole-house balanced ventilation
    • Replaces stale and polluted indoor air with fresh outdoor air minimizing negative or positive pressure in the house
    • The energy recovery enthalpic core slows moisture transfer from outdoor air and indoor air (depending which has higher humidity levels)
    • Year round energy recovery with the benefit of fresh air and energy savings
    • Defrost mechanism prevents ice build up in the system core
  • Whole House Mechanical Ventilation (WHMV) Specifier

    Code compliant solutions for one and two family dwellings and townhouses up to three stories
     

    To better serve you in determining your customers’ whole house mechanical ventilation (otherwise known as continuous ventilation) needs, Broan-NuTone has developed this on-line tool.  With our CodeKey Specifier you can be confident that the products choose will meet the latest codes and regulations.  Use this tool to make your specification job easier.


    Let’s get started by selecting the state where the dwelling unit will be located. CLICK HERE


  • Video Links

  • Airflow (CFM)60-142
    Anti-freeze Setting (Approved for Unheated Space)Yes
    Assembled Depth (in)34.6"
    Assembled Width (in)13.25"
    Assembly RequiredNo
    Built-in TimerN/A
    Carton Weight (lb) - from price book75 lbs.
    cETL ListedNo
    ColorTan
    Coverage Area (sq ft)3,000 - 4,500 sq. ft.
    CSA ListedNo
    cUL ListedYes
    Damper includedYes
    ENERGY STAR® qualifiedNo
    ETL ListedNo
    Fan SpeedsLow
    High
    Filter Life (months)Clean Filter As Recommended In Owners Manual
    Filter Type30 ppi washable reticulated foam
    Hardware IncludedYes
    HVI CertifiedYes
    InstallationVertical / Horizontal
    Item Weight65 lbs.
    Maximum Air Flow Capacity (CFM)142 CFM
    Maximum Amperage (amps)1.4 Amps
    Mounting LocationCloset
    Utility Room
    Attic
    Basement
    Mounting StyleSuspension by chains and springs
    Number of Filters2
    Product Height (in)21.1"
    Product Length (in)34.6"
    Product Weight (lb) - from spec sheet65 lbs.
    Product Width (in)13.25"
    Rectangular Duct SizeN/A
    Round Duct Diameter6"
    Round Fresh Air Duct Diameter6"
    Sound Level (sones)Information Forthcoming
    Sq. Ft.4,500
    Switch TypeOptional
    Temperature SensorYes
    UL ListingYes
    Voltage (volts)120 Volts
    Warranty Information2 years on parts - 5 years on core
  • (4 Questions : 4 Answers)

    Product Q&A

    Ask your questions. Share your answers.

     
     
    « Back
     
     
    Has staff answer
    ERV200HC
     
    1 answer

    What kind of recovery core does the Guardian ERV 200 HC have?

    Customer avatar
    by
    Froggy
    Medina, MN, USA
    We recently moved into a home that has a Guardian ERV 200 HC system. I would like to clean the filters and the recovery core but don't know if it's Polypropylene (can be washed# or Enthalpic paper #cannot be washed). My guess is that the recovery core has not been clean since it was installed in 2001!
    Age: 55-64
    Gender: Male
    1 month, 3 weeks ago
    Customer avatar
    by
    Froggy
    Medina, MN, USA
    0points
    0out of 0found this question helpful.
    Was this helpful?helpful0unhelpful0

    Answers

    Answer: 
    Thank you for your question on the model ERV200HC energy recovery ventilator. The energy recovery core can be cleaned. Please contact the Technical Service Department at 800-637-1453 for assistance.
    1 month, 2 weeks ago
    Customer avatar
    by
    Read all my Q&A
     
    Please wait while more information about BroanCustomerService is loaded.
    Additional information about BroanCustomerService could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0
    Has staff answer
    ERV100HC
     
    1 answer

    New filter

    Customer avatar
    by
    Julie
    Cedar Falls, IA, USA
    I need a filter for this model erv100hc. It's part 15 in the diagram. It's the big square filter not the foam filters.
    Age: 25-34
    Gender: Male
    5 months, 1 week ago
    Customer avatar
    by
    Julie
    Cedar Falls, IA, USA
    0points
    0out of 0found this question helpful.
    Was this helpful?helpful0unhelpful0

    Answers

    Answer: 
    Thank you for your question on the model ERV100HC energy recovery ventilator. Please contact the Technical Service Department at 800-637-1453 for assistance.
    5 months ago
    Customer avatar
    by
    Read all my Q&A
     
    Please wait while more information about BroanCustomerService is loaded.
    Additional information about BroanCustomerService could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0
    Has staff answer
    ERV200HC
     
    1 answer

    How to connect to furnance

    Customer avatar
    by
    Scott J
    Plymouth, MN, USA
    I had the ERV200HC installed to come on when my furnance turned on. I have since, replaced the furnance with a Goodman MCV95 unit and the installer claims that it cannot be connected to turn on with the furnance?
    Is this correct? If not who can provide me with details to do this?
    Thank you
    Age: 45-54
    Gender: Male
    1 year, 1 month ago
    Customer avatar
    by
    Scott J
    Plymouth, MN, USA
    0points
    0out of 0found this question helpful.
    Was this helpful?helpful0unhelpful0

    Answers

    Answer: 
    Thank you for your question on the model ERV200HC energy recovery ventilator. Please contact our Technical Service Department at 800-637-1453 for assistance.
    1 year, 1 month ago
    Customer avatar
    by
    Read all my Q&A
     
    Please wait while more information about BroanCustomerService is loaded.
    Additional information about BroanCustomerService could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0
    Has staff answer
    ERV200HC
     
    1 answer

    BROAN ERV200HC How do I remove the cover to clean the filters?

    Customer avatar
    by
    Kathi
    Spring Park, MN, USA
    How do I get the cover off? The serial # is 8H85 000205297
    Age: 55-64
    Gender: Female
    1 year, 8 months ago
    Customer avatar
    by
    Kathi
    Spring Park, MN, USA
    0points
    0out of 0found this question helpful.
    Was this helpful?helpful0unhelpful0

    Answers

    Answer: 
    On our website, www.broan.com, put in your model number at the top of the page. Once the model number comes up, click on Additional Information. From there you can download the USER MANUAL, which contains great graphics, will be very helpful in the use and care of the unit. with great graphics.

    To remove the cover, unlatch the door. Lift the panel towards you. Hold it firmly and hit on the right side of the panel. The door should slide to the left.
    1 year, 8 months ago
    Customer avatar
    by
    Read all my Q&A
     
    Please wait while more information about BroanCustomerService is loaded.
    Additional information about BroanCustomerService could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0
    1 of 1