4 Additional Images

HRV100HHeat Recovery Ventilator, 64 – 146 CFM

  • Overview
  • Continuous Ventilation Selector
  • Video Links
  • Specifications
  • Where To Buy
  • Reviews
  • Answers
  • Significantly increase the quality of the air inside your home with a BROAN HRV. Allergens and pollutants within your home can have negative effects on your health. By adding a BROAN HRV to your home's ventilation system, you can ensure that the air within your home is being circulated and the pressure remains balanced.

    The BROAN HRV100H is perfect for 3,000-4,500 sq. ft. single-family homes in colder climates with longer heating season. Designed to recover heat from the stale outgoing air and transfer it to the fresh incoming air, it eliminates accumulated pollutants and reduces excessive winter moisture build-up, while maintaining an optimum air quality and an ideal relative humidity. The units are durable, reliable and offer high performance that will be sure to add value and quality to any home. An easy-access side panel makes maintenance quick and convenient with the ability to remove all parts in five minutes or less.

    • Ideal for homes 3,000 to 4,500 square feet
    • Delivers 64 to 146 CFM of whole-house balanced ventilation
    • Replaces stale and polluted indoor air with fresh outdoor air minimizing negative or positive pressure in the house
    • Our heat recovery core allows outgoing stale air to temper fresh incoming air without cross contamination
    • Defrost mechanism prevents ice build up in the system core
  • Whole House Mechanical Ventilation (WHMV) Specifier

    Code compliant solutions for one and two family dwellings and townhouses up to three stories
     

    To better serve you in determining your customers’ whole house mechanical ventilation (otherwise known as continuous ventilation) needs, Broan-NuTone has developed this on-line tool.  With our CodeKey Specifier you can be confident that the products choose will meet the latest codes and regulations.  Use this tool to make your specification job easier.


    Let’s get started by selecting the state where the dwelling unit will be located. CLICK HERE


  • Video Links

  • Airflow (CFM)64-146
    Anti-freeze Setting (Approved for Unheated Space)Yes
    Assembled Depth (in)34.6"
    Assembled Width (in)13.25"
    Assembly RequiredNo
    Built-in TimerN/A
    Carton Weight (lb) - from price book74 lbs.
    cETL ListedNo
    ColorTan
    Coverage Area (sq ft)3,000 - 4,500 sq. ft.
    CSA ListedNo
    cUL ListedYes
    Damper includedYes
    ENERGY STAR® qualifiedNo
    ETL ListedNo
    Fan SpeedsLow
    High
    Filter Life (months)Clean Filter As Recommended In Owners Manual
    Filter Type30 ppi washable reticulated foam
    Hardware IncludedYes
    HVI CertifiedYes
    InstallationVertical / Horizontal
    Item Weight65 lbs.
    Maximum Air Flow Capacity (CFM)146 CFM
    Maximum Amperage (amps)1.4 Amps
    Mounting LocationCloset
    Utility Room
    Attic
    Basement
    Mounting StyleSuspension by chains and springs
    Number of Filters2
    Product Height (in)21.1"
    Product Length (in)34.6"
    Product Weight (lb) - from spec sheet65 lbs.
    Product Width (in)13.25"
    Rectangular Duct SizeN/A
    Round Duct Diameter6"
    Round Fresh Air Duct Diameter6"
    Sound Level (sones)Information Forthcoming
    Sq. Ft.4,500
    Switch TypeOptional
    Temperature SensorYes
    UL ListingYes
    Voltage (volts)120 Volts
    Warranty Information2 years on parts - 10 years on core
  • Rated 5 out of 5 by 1 reviewer.
    Rated 5 out of 5 by Did a good job of eliminating moisture 1st year; haven't used since as gets house too dry. Sure had a time trying to figure out how to use your item - instruction book rather confusing. I do think as a woman owning this item your manual could be more specific. Really like the fresh air intake EXCEPT that the vent outside has to be cleaned off with a tooth brush often. Live on a very dusty road and also have a lot of misquitoes inside box. Haven't used the dehumidifer portion during the last couple winters except in beginning of season - humidity too low in house. Dealer mentioned other people don't use it either. Wonder if that works against the high efficient furnace! August 22, 2013
    1-1 of 1
  • (11 Questions : 12 Answers)

    Product Q&A

    Ask your questions. Share your answers.

     
     
    « Back
     
     
    Has staff answer
    HRV100H
     
    2 answers

    HRV100H Unite VT1W Control - Won't stay running

    Customer avatar
    by
    Minnesota, USA
    Read all my Q&A
     on HRV100H
     
    Please wait while more information about SameHomeowner is loaded.
    Additional information about SameHomeowner could not be loaded.
    HRV100H unit will run for 10mins sometimes longer and stop whether switched on manual or remote but wont come on again til unplug and replug. What could be the matter?
    Age: 45-54
    Gender: Male
    4 months, 3 weeks ago
    Customer avatar
    by
    Minnesota, USA
    Read all my Q&A
     
    Please wait while more information about SameHomeowner is loaded.
    Additional information about SameHomeowner could not be loaded.
    0points
    0out of 0found this question helpful.
    Was this helpful?helpful0unhelpful0

    Answers

    Answer: 
    Thank you for your question on the model HRV100H heat recovery ventilator. Please contact the Technical Service Department at 800-637-1453 for assistance.
    4 months, 3 weeks ago
    Customer avatar
    by
    Read all my Q&A
     
    Please wait while more information about BroanCustomerService is loaded.
    Additional information about BroanCustomerService could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0

    Answer: 
    Just a follow-up. I talked with Broan's Tech Service Dept. and they said it sounds like the thermistor is going. Its abt a $30part. I decided to clean it. There was quite a buildup of crud and so far so good its working. If it stops in the near future I will know it needs to be changed out. Thank you Erica in Tech Serv for your quick and knowledgeable answer.
    Age: 45-54
    Gender: Male
    4 months, 3 weeks ago
    Customer avatar
    by
    Minnesota, USA
    Read all my Q&A
     
    Please wait while more information about SameHomeowner is loaded.
    Additional information about SameHomeowner could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0
    Control switch is always making noise, what should we do? Is it repairable or needs to be replaced whole controller.
    5 months ago
    Customer avatar
    by
    Ravi
    MN
    0points
    0out of 0found this question helpful.
    Was this helpful?helpful0unhelpful0

    Answers

    Answer: 
    Thank you for your question on the model VT1W control for the HRV200H heat recovery ventilator. Please contact the Technical Service Department at 800-637-1453 for assistance.
    5 months ago
    Customer avatar
    by
    Read all my Q&A
     
    Please wait while more information about BroanCustomerService is loaded.
    Additional information about BroanCustomerService could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0
    Has staff answer
    HRV200H
     
    1 answer

    My unit won't turn on

    Customer avatar
    by
    Mario
    Woodbury
     on HRV200H
    I have checked the outlet and there appears to be no problem but the unit wont start.
    Any trouble shooting ideas?
    Age: 55-64
    Gender: Male
    5 months, 4 weeks ago
    Customer avatar
    by
    Mario
    Woodbury
    0points
    0out of 0found this question helpful.
    Was this helpful?helpful0unhelpful0

    Answers

    Answer: 
    Thank you for your question on the model HRV200H heat recovery ventilation system. Please contact the Technical Service Department at 800-637-1453 for assistance.
    5 months, 4 weeks ago
    Customer avatar
    by
    Read all my Q&A
     
    Please wait while more information about BroanCustomerService is loaded.
    Additional information about BroanCustomerService could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0
    Age: Over 65
    Gender: Male
    7 months ago
    Customer avatar
    by
    Bill
    Minot, ND, USA
    0points
    0out of 0found this question helpful.
    Was this helpful?helpful0unhelpful0

    Answers

    Answer: 
    Thank you for your question on the model HRV100H heat recovery ventilator. Please contact the Technical Service Department at 800-637-1453 for assistance.
    7 months ago
    Customer avatar
    by
    Read all my Q&A
     
    Please wait while more information about BroanCustomerService is loaded.
    Additional information about BroanCustomerService could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0
    Has staff answer
    HRV100H
     
    1 answer

    where does the thermistor mount on my HRV100H?

    Customer avatar
    by
    D
    Bloomington, MN, USA
     on HRV100H
    I had to install a new thermistor (SV12895) on my HRV100H unit but I can't tell where it was originally mounted. Can you send me a diagram of where in the cabinet it should be so that I can properly reinstall it?
    Age: 45-54
    Gender: Male
    8 months ago
    Customer avatar
    by
    D
    Bloomington, MN, USA
    0points
    0out of 0found this question helpful.
    Was this helpful?helpful0unhelpful0

    Answers

    Answer: 
    Thank you for your question on the model HRV100H heat recovery ventilator. Please contact the Technical Service Department at 800-637-1453 for assistance.
    8 months ago
    Customer avatar
    by
    Read all my Q&A
     
    Please wait while more information about BroanCustomerService is loaded.
    Additional information about BroanCustomerService could not be loaded.
    0points
    0out of 0found this answer helpful.
    Was this helpful?helpful0unhelpful0
    2 next>>